Alarm List
Alarm Number (1000 to 1999)
Alarm List-292
71 An error occurred in the DNS
resolver setting of the
Ethernet function.
Setting error (1)Check the following settings.
∙ The domain name
∙ The DNS related settings
∙ The DHCP server operation
∙ The network status
YCP21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP21 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YCP21
board, and then remove the CF from the failure YCP21 board to insert
it into the new YCP21 board.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
72 The parameter setting error
occurred in the DNS resolver
setting of the Ethernet
function.
Setting error (1)Check the following settings.
∙ The domain name
∙ The DNS related settings
∙ The DHCP server operation
∙ The network status
YCP21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP21 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YCP21
board, and then remove the CF from the failure YCP21 board to insert
it into the new YCP21 board.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
73 The mode error occurred in
the DNS resolver setting of
the Ethernet function.
Setting error (1)Check the following settings.
∙ The domain name
∙ The DNS related settings
∙ The DHCP server operation
∙ The network status
Alarm
Number
Alarm Name Sub
Code
Meaning Cause Remedy