Alarm List
Alarm Number (4000 to 4999)
Alarm List-468
11 The setting value of
measurement item (FT) is
incorrect.
Setting error (1)Reset the alarm.
(2)Correct the setting value of a measurement item.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
12 The data for the vision
execution command is
incorrect.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
48 The number of waiting
commands sent by Vision
sensor exceeded the limit.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)Check the command sent by Vision sensor
(3)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4125 TRANS ERROR
(WELD PULSE
COND)
1 File access error Communication error (1)Reset the alarm.
(2)If the alarm occurs again, check the communication setting and
communication wiring is correct.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
2 File data error Communication error (1)Reset the alarm.
(2)If the alarm occurs again, check the setting of communication or file
data is correctly set.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
3 Calibration execution error Communication error (1)Reset the alarm.
(2)If the alarm occurs again, check the setting of communication or
transmission side data is correctly set.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy