Alarm List
Alarm Number (4000 to 4999)
Alarm List-486
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4137 WRONG EXECUTION
OF SETUALM INST
1 Alarm code specification error Setting error (1)Reset the alarm.
(2)Check the following settings.
∙ Alarm code
Specify the alarm in the range 8000 to 8999.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
2 Task specification error Setting error (1)Reset the alarm.
(2)Check the following settings.
∙ Task specification
Specify the task in the range 0 to 15.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
3 Motion mode specification
error
Setting error (1)Reset the alarm.
(2)Check the following settings.
∙ Motion mode specification
Set the motion mode to 0 or 1.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4138 WRONG EXECUTION
OF SVON INST
Connection failure (1)Reset the alarm.
(2)Check the following settings.
∙ Short-circuit the external servo ON (EXSVON) of MXT terminal block.
Setting error (1)Reset the alarm.
(2)Check the following settings.
∙ The concurrent I/O signal #80031 (servo ON condition1) ON
∙ The concurrent I/O signal #80033 (servo ON condition2) ON
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy