Alarm List
Alarm Number (4000 to 4999)
Alarm List-591
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
6 An error occurred in the
acquisition process of domain
during the network service
data creation process of the
Ethernet function.
Setting error (1)Check the following settings.
∙ The DHCP server operation (If the DHCP is used)
∙ The network status (If the DHCP is used)
YCP21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP21 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YCP21
board, and then insert the CF card which inserted original YCP21
board into the new YCP21 board.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
7 An error occurred in the
acquisition process of SNTP
server during the network
service data creation process
of the Ethernet function.
Setting error (1)Check the following settings.
∙ The DHCP server operation (If the DHCP is used)
∙ The network status (If the DHCP is used)
YCP21 board failure (1)Turn the power OFF then back ON.
(2)If the alarm occurs again, replace the YCP21 board. Save the
CMOS.BIN before replace the board to be safe. Replace the YCP21
board, and then insert the CF card which inserted original YCP21
board into the new YCP21 board.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
8 An error occurred in the
acquisition process of host
name during the network
service data creation process
of the Ethernet function.
Setting error (1)Check the following settings.
∙ The DHCP server operation (If the DHCP is used)
∙ The network status (If the DHCP is used)
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy