Alarm List
Alarm Number (4000 to 4999)
Alarm List-651
8 Error from welder 8. Arc welding power source
error
The data may not have been correctly saved when the welding
conditions are recorded because of a power failure, etc. Reset the
system after saving the changed parameters. (See the manual of
MOTOWELD "4.2.10 System Reset")
If the error occurs again, the board may be broken. Contact your
Yaskawa representative.
210 Sub code: Error No. from
welder.
Arc welding power source
error
The data may not have been correctly saved when the welding
conditions are recorded because of a power failure, etc. Reset the
system after saving the changed parameters. (See the manual of
MOTOWELD "4.2.10 System Reset")
If the error occurs again, the board may be broken. Contact your
Yaskawa representative.
4269 MOTOWELD
STARTING SIGNAL
ERROR
1 Error from welder 1. Arc welding power source
error
Check again the operation timing or signal cable connections. The
same error may occur at momentary power failure.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
2 Error from welder 2. Arc welding power source
error
Check again the operation timing or signal cable connections. The
same error may occur at momentary power failure.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
3 Error from welder 3. Arc welding power source
error
Check again the operation timing or signal cable connections. The
same error may occur at momentary power failure.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4 Error from welder 4. Arc welding power source
error
Check again the operation timing or signal cable connections. The
same error may occur at momentary power failure.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy