Alarm List
Alarm Number (4000 to 4999)
Alarm List-652
5 Error from welder 5. Arc welding power source
error
Check again the operation timing or signal cable connections. The
same error may occur at momentary power failure.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
6 Error from welder 6. Arc welding power source
error
Check again the operation timing or signal cable connections. The
same error may occur at momentary power failure.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
7 Error from welder 7. Arc welding power source
error
Check again the operation timing or signal cable connections. The
same error may occur at momentary power failure.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
8 Error from welder 8. Arc welding power source
error
Check again the operation timing or signal cable connections. The
same error may occur at momentary power failure.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
601 Sub code: Error No. from
welder.
Arc welding power source
error
Check again the operation timing or signal cable connections. The
same error may occur at momentary power failure.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
4270 MOTOWELD NO
WELDING TYPE
1 Error from welder 1. Arc welding power source
error
Select a correct welding process in the using the welding user file.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
2 Error from welder 2. Arc welding power source
error
Select a correct welding process in the using the welding user file.
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy