Alarm List
Alarm Number (4000 to 4999)
Alarm List-741
3 The set data for real type
variable area is incorrect.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4 The set data for character-
string type variable area is
incorrect.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
5 The set data for robot-axis
position-type variable area is
incorrect.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
6 The set data for base-axis
position-type variable (S1D
parameter) area is incorrect.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
7 The set data for station-axis
position-type variable (S1D
parameter) area is incorrect.
Software operation error
occurred
(1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
4435 UNDEFINED LOCAL-
VARIABLE
0 The byte type variable is not
defined.
Setting error (1)Check the following settings.
∙ Set the number of local variables to be used in the job header.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
1 The integer type variable is
not defined.
Setting error (1)Check the following settings.
∙ Set the number of local variables to be used in the job header.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
2 The double-precision integer-
type variable is not defined.
Setting error (1)Check the following settings.
∙ Set the number of local variables to be used in the job header.
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy