Alarm List
Alarm Number (4000 to 4999)
Alarm List-778
138 Notch filter supported
acceleration and deceleration
tuning: Notch filter function
setting error
Setting error (1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
139 Notch filter supported
acceleration and deceleration
tuning: Notch filter (z2) setting
error
Setting error (1)Reset the alarm, and then try again.
(2)If the alarm occurs again, save the CMOS.BIN in maintenance
mode, and then contact your Yaskawa representative about
occurrence status (operating procedure).
147 NON ACTIVATION of Servo
Simulation function error
Setting error (1)Check the following settings.
∙ Enable Servo Simulation Function.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
149 The setting error of vibration
suppression filter for
SVSPOTMOV
Setting error (1)Check the following settings.
∙ Confirm that the threshold value for the vibration suppression filter
should be larger than the one in previous table.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
150 the setting error of time
constant for the vibration
suppression filter for
SVSPOTMOV
Setting error (1)Check the following settings.
Confirm that the time constant for vibration suppression filter for
SVSPOTMOV must be the different value of Kp.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
152 the setting error of the number
for vibration suppression filter
for SVSPOTMOV
Setting error (1)Check the following settings.
Confirm that the number of the tables activated for vibration filter is
less than 5.
other If the alarm occurs again, save the CMOS.BIN in maintenance mode,
and then contact your Yaskawa representative about occurrence
status (operating procedure).
Alarm
Number
Alarm Name
Sub
Code
Meaning Cause Remedy