HOA Keypad Display Fault Name
A damaged motor cable is creating a short
circuit
Check the motor cable.
Remove the short circuit and reapply power to the drive
Check the resistance between the cable and the ground terminal .
Replace the cable.
Excessive leakage current at the drive
output
Reduce the carrier frequency.
Reduce the amount of stray capacitance.
The drive started to run during a current
offset fault or while coasting to a stop
Set b3-01 to 1 to enable Speed Search at Start.
Perform Speed Search 1 or 2 (H1-oo = 61 or 62) via one of the external terminals.
Hardware problem
If the problem continues, replace the control board or the entire drive. Contact Yaskawa or a Yaskawa
representative for instructions on replacing the control board.
HOA Keypad Display Fault Name
HFB
High Feedback
The feedback signal is too high.
Cause Possible Solution
The feedback signal has risen above the
level set in P1-11, High Feedback Level,
for the time set in P1-12, High Feedback
Level Fault Delay Time.
This is effective only when P1-13, High
Feedback Selection, is set to 0 (Fault and
digital outt).
Set the High Feedback fault characteristics in P1-11 and P1-12.
Drive response to this condition is controlled by P1-13, High Feedback Selection. Auto-restart of this fault
is controlled by L5-41, High Feedback Fault Retry Selection.
HOA Keypad Display Fault Name
HIAUX
High PI Aux Lvl
High PI Auxiliary Feedback Level
Cause Possible Solution
PI Aux Feedback has risen above the Q6-12
level for longer than the time set in Q6-13
and the drive is running inAUTO, and
output frequency is greater than zero.
Lower the PI Aux Feedback level
Adjust parameters Q6-12 and Q6-13.
HOA Keypad Display Fault Name
HIFLO
High Flow
High Flow
The meter has detected a high flow condition.
Cause Possible Solution
The flow is too high Reduce the flow
The measured water flow has risen above
the P6-17 level for the time set in P6-18.
This is only effective when P6-19, High
Flow Select is set to 2 (fault).
Set the High Flow fault characteristics in P6-17 and P6-18.
Drive response to this condition is controlled by P6-19, High Flow Select.
Auto-restart of this fault is controlled by P6-19, High Flow Select.
HOA Keypad Display Fault Name
HISUC
High Suction
High Section Pressure
Cause Possible Solution
The suction pressure has risen above the
level set in Q5-12 for longer than the time
set in Q5-13. This is only effective when
Q5-14, High Suction Pressure Behavior
Select, is set to 2 (fault).
Reduce the system pressure.
Set the High Suction Pressure fault characteristics in Q5-12, Q5-13, and Q5-18.
Drive response to this condition is controlled by Q5-14, High Suction Pressure Behavior Select.
Auto-restart of this fault is controlled by Q5-14, High Suction Pressure Behavior Select and Q5-15, Suction
Pressure Auto-restart Time.
HOA Keypad Display Fault Name
HWL
High Water Level
The “High Water Level” digital input is active (H1-0o = 90).
Cause Possible Solution
The Low Water Level switch is activated or
P1-31, High Water Digital Input
Configuration, is programmed incorrectly.
Lower the water level and/or adjust the High Water Level switch.