7 Utility Functions (Fn)
7-18
7.10 Write Prohibited Setting (Fn010)
This function prevents changing parameters by mistake and sets restrictions on the execution of the utility
function.
Parameter changes and execution of the utility function become restricted in the following manner when Write
prohibited (P.0001) is assigned to the write prohibited setting parameter (Fn010).
Parameters: Cannot be changed. If you attempt to change it, "NO-OP" will flash on the display and the
screen will return to the main menu.
Utility Function: Some functions cannot be executed. (Refer to the following table.) If you attempt to exe-
cute these utility functions, "NO-OP" will flash on the display and the screen will return to the main menu.
(1) Preparation
There are no tasks that must be performed before the execution.
Parameter
No.
Function
Write Prohibited
Setting
Reference
Section
Fn000
Alarm history display Executable 7.2
Fn002
JOG operation Cannot be executed 7.3
Fn003
Origin search Cannot be executed 7.4
Fn004
Program JOG operation Cannot be executed 7.5
Fn005
Initializing parameter settings Cannot be executed 7.6
Fn006
Clearing alarm history Cannot be executed 7.7
Fn008
Absolute encoder multiturn reset and encoder alarm reset Cannot be executed 5.9.4
Fn009
Automatic tuning of analog (speed, torque) reference offset Cannot be executed
5.3.2
5.5.2
Fn00A
Manual servo tuning of speed reference offset Cannot be executed 5.3.2
Fn00B
Manual servo tuning of torque reference offset Cannot be executed 5.5.2
Fn00C
Offset adjustment of analog monitor output Cannot be executed 7.8
Fn00D
Gain adjustment of analog monitor output Cannot be executed 7.9
Fn010
Write prohibited setting 7.10
Fn011
Servomotor model display Executable 7.11
Fn012
Software version display Executable 7.12
Fn013
Multiturn limit value setting change when a multiturn limit dis-
agreement alarm occurs
Cannot be executed 5.9.7
Fn01B
Vibration detection level initialization Cannot be executed 7.13
Fn01E
Display of multi-winding drive unit and servomotor ID Executable 7.14
Fn201
Advanced autotuning Cannot be executed 6.2.2
Fn203
One-parameter tuning Cannot be executed 6.3.2
Fn204
Anti-resonance control adjustment function Cannot be executed 6.4.2
Fn205
Vibration suppression function Cannot be executed 6.5.2
Fn206
EasyFFT Cannot be executed 7.15
Fn207
Online vibration monitor Cannot be executed 7.16