EasyManua.ls Logo

YASKAWA JUSP-MD D01A Series - Parameters

YASKAWA JUSP-MD D01A Series
363 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10 Appendix
10.2.2 Parameters
10-14
Pn008
2
Application Function Select
Switch 8
0000 to 7121
0000 After restart Setup
Pn009
2
Application Function Select
Switch 9
0000 to 0111
0010 After restart Tuning
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When Enabled
Classifi-
cation
Reference
Section
Lowered Battery Voltage Alarm/Warning Selection
Reference
Section
0 Outputs alarm (A.830) for lowered battery voltage.
5.9.3
1 Outputs warning (A.930) for lowered battery voltage.
Reserved (Do not change.)
Warning Detection Selection
Reference
Section
0 Detects warning.
9.2.1
1 Does not detect warning (except for A.971, A.9b0, and A.9b1).
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.

Automatic Offset Adjustment of Motor Current Detection Signals
Reference
Section
0 Does not execute automatic adjustment.
1 Executes automatic adjustment when the main circuit power supply is turned ON.
Current Control Method Selection
Reference
Section
0 Current control method 1
6.6.3
1 Current control method 2
Speed Detection Method Selection
Reference
Section
0 Speed detection 1
6.6.5
1 Speed detection 2
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.


Table of Contents