No.
Parameter Display Selection
Reference 
Section
0 Setup parameters
2.3.1
1 All parameters
Alarm Gr.2 Stop Method Selection
Reference 
Section
0 Stops the motor by setting the speed reference to "0".
5.2.5
1 Same setting as Pn001.0 (Stops the motor by applying DB or by coasting).
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.
Reserved (Do not change.)
Dynamic Brake Signal Selection
When 
Enabled
Classification
Reference 
Section
0 Enables the control of an NO contactor 
(The dynamic brake is activated when current is 
supplied to the contactor coil.)
After restart Setup
3.9.3
1 Enables the control of an NC contactor 
(The dynamic brake is activated when current is not 
supplied to the contactor coil.)
Reserved (Do not change.)
Overtravel Warning Detection Selection
When 
Enabled
Classification
Reference 
Section
0 Does not detect overtravel warning.
Immediately Setup
5.2.3
1 Detects overtravel warning.
4th 3rd 2nd 1st
digit digit digit digit
n.