10.2 List of Parameters
10-15
10
Appendix
Pn00B
2
Application Function Select
Switch B
0000 to 1111
0000 After restart Setup
Pn00D
2
Application Function Select
Switch D
0000 to 1011
0000
Setup
Pn010
2
Axis Address Selection (for
UART/USB communications)
0000 to 007F
0001 After restart Setup
(cont’d)
Parameter
No.
Size
Name
Setting
Range
Units
Factory
Setting
When Enabled
Classifi-
cation
Reference
Section
Parameter Display Selection
Reference
Section
0 Setup parameters
2.3.1
1 All parameters
Alarm Gr.2 Stop Method Selection
Reference
Section
0 Stops the motor by setting the speed reference to "0".
5.2.5
1 Same setting as Pn001.0 (Stops the motor by applying DB or by coasting).
Reserved (Do not change.)
Reserved (Do not change.)
4th 3rd 2nd 1st
digit digit digit digit
n.

Reserved (Do not change.)
Dynamic Brake Signal Selection
When
Enabled
Classification
Reference
Section
0 Enables the control of an NO contactor
(The dynamic brake is activated when current is
supplied to the contactor coil.)
After restart Setup
3.9.3
1 Enables the control of an NC contactor
(The dynamic brake is activated when current is not
supplied to the contactor coil.)
Reserved (Do not change.)
Overtravel Warning Detection Selection
When
Enabled
Classification
Reference
Section
0 Does not detect overtravel warning.
Immediately Setup
5.2.3
1 Detects overtravel warning.
4th 3rd 2nd 1st
digit digit digit digit
n.
