3.9 Selecting and Connecting a Dynamic Brake Unit
3-41
3
Wiring and Connection
3.9 Selecting and Connecting a Dynamic Brake Unit
To use the dynamic brake (DB), externally connect a dynamic brake unit or dynamic brake resistor to the
SERVOPACK to process the dynamic braking energy.
Set Pn001 to n.2 if you do not use the dynamic brake. In this case, it is not necessary to connect a
dynamic brake unit.
3.9.1 Selection
Use the following tables to select a dynamic brake unit or dynamic brake resistor.
(1) Using a Yaskawa Dynamic Brake Unit
(2) Using a Dynamic Brake Resistor from Another Company
To order a dynamic brake unit, contact the manufacturer directly.
Use the following dynamic brake contactors and surge absorption units.
Use either a head-on or side-on main circuit surge absorption unit.
3.9.2 Selecting the Cable for the Dynamic Brake Unit
Use one of the following cables to connect the dynamic brake unit or dynamic brake contactor to CN115 on
the SERVOPACK.
• A dynamic brake unit is required for each SERVOPACK.
• Set the dynamic brake in parameter Pn001 of the multi-winding drive unit. Do not mis-
takenly change the SERVOPACK parameter. To enable a new parameter setting, turn
the control power supply OFF and ON again.
Main Circuit
Power Supply
Voltage
SERVOPACK
Model:
SGDV-
Dynamic Brake
Unit Model
Resistance
Specifications
(Star Wiring )
Dynamic Brake Contactor and
Surge Absorption Unit
Three-phase
400 V
101J JUSP-DB04-E 180 W, 0.8 Ω × 3 Built into dynamic brake unit.
Main Circuit
Power Supply
Voltage
Model Manufacturer
Required
Resistance
Three-phase
400 V
GR series Japan Resistor Mfg. Co., Ltd. 0.8 Ω or greater
Name Model Manufacturer
Contactor
SC-4-1/G
Coil: 24 VDC
Fuji Electric Co., Ltd.
Main circuit surge
absorption unit
*
Head-on type SZ-ZM1
Side-on type SZ-ZM2
Coil surge absorption unit SZ-Z4
Cable Model
Cable
length
Cable End Processing on
Contact Coil End of Cable
Remarks Manufacturer
JZSP-CVD00-1A5-E 1.5 m
Crimp terminals are attached
(M3.5).
Red: Pin 1 (DB24)
Black: Pin 3 (DBON)
Yaskawa Controls Co.,
Ltd.
JZSP-CVD00-03-E 3 m