EasyManuals Logo
Home>YASKAWA>Controller>MP Series

YASKAWA MP Series User Manual

YASKAWA MP Series
557 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #216 background imageLoading...
Page #216 background image
6.2 Motion Command Details
6.2.7 Relative Position Mode (STEP) (Step Mode)
6-51
Motion Commands
[ b ] Execution when Aborted
[ c ] Execution when Aborting by Changing the Command
[ d ] Execution when an Alarm Occurs
Undefined length of time1 scan
OW09, bit 1 (ABORT)
OW08 = 8 (STEP)
IW08 = 8 (STEP)
IW09, bit 0 (BUSY)
IW09, bit 8 (COMPLETE)
IW09, bit 3 (FAIL)
IW0C, bit 0 (DEN)
IW0C, bit 1 (POSCOMP)
Undefined length of time1 scan
OW08 = 8 (STEP)
IW08 = 8 (STEP)
IW09, bit 0 (BUSY)
IW09, bit 8 (COMPLETE)
IW09, bit 3 (FAIL)
IW0C bit 0 (DEN)
IW0C, bit 1 (POSCOMP)
Undefined length of time
Alarm
1 scan
OW08 = 8 (STEP)
IW08 = 8 (STEP)
IW09, bit 0 (BUSY)
IW09, bit 8 (COMPLETE)
IW09, bit 3 (FAIL)
IW0C, bit 0 (DEN)
IW0C, bit 1 (POSCOMP)

Table of Contents

Other manuals for YASKAWA MP Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA MP Series and is the answer not in the manual?

YASKAWA MP Series Specifications

General IconGeneral
BrandYASKAWA
ModelMP Series
CategoryController
LanguageEnglish

Related product manuals