9.2 Setting Procedure of Absolute Position Detection Function
9.2.2 Initializing the Absolute Encoder
9-5
Absolute Position Detection
9.2.2 Initializing the Absolute Encoder
Absolute encoders can be initialized as follows:
• SERVOPACK Procedure
Refer to the manual for the SERVOPACK for details.
• Panel Operator or Digital Operator Procedure
Refer to the manual for the SERVOPACK for details.
• ABS_RST Command Procedure
Refer to 6.2.21 Absolute Encoder Reset (ABS_RST) for details.
For details on the procedure for initializing SERVOPACKS, refer to Appendix C Initializing the Absolute Encoder.
Initialize the absolute encoder in the following situations.
When the absolute position detection system is started up for the first time
When number of rotations from the absolute reference position needs to be initialized to 0
When a Servomotor has been left with no battery connected to the absolute encoder
When an alarm which is related the absolute position detection system occurs