Programming 5 - 29
If one of the custom V/f patterns is selected, then parameters E1-04 through E1-13 will determine the V/F pattern.
Table 3 is for 240V class units only, for 480V class units multiply the voltage value by 2.
" E1-04 Maximum Output Frequency
Setting Range: 0.0 to 120.0 Hz
Factory Default: 60.0 Hz
Table 3 Preset V/f Patterns
Specifications E1-03 V/f Pattern *1 Specifications E1-03 V/f Pattern *1
General-purpose
50Hz 0
High Starting Torque *2
50Hz
High
Starting
Torque 1
8
High
Starting
Torque 2
9
60Hz Saturation
1
F
60Hz
High
Starting
Torque 1
A
50Hz Saturation 2
High
Starting
Torque 2
B
72Hz 3
High Speed Operation
90Hz C
Variable Torque
50Hz
Variable
Torque 1
4
120Hz D
Variable
Torque 2
5
60Hz
Variable
Torque 1
6
Variable
Torque 2
7
IMPORTANT
When a factory Initialization is performed, the setting of E1-03 is unaffected but the settings of E1-04 through
E1-13 are returned to their factory default settings.
(Hz)
(V)
230
17
10
01.32.5 50
0
230
(V)
28
22
15
13
(Hz)
01.32.5 50
9
8
(Hz)
01.53.0 50 60
17
10
2
1
F
(V)
230
230
(V)
28
22
17
13
(Hz)
01.53.0
B
A
60
(Hz)
01.53.0 60 72
17
10
3
(V)
230
(Hz)
01.53.0 60 90
17
10
C
(V)
230
230
(V)
57
40
10
9
(Hz)
0 1.3 25 50
5
4
(Hz)
01.53.0 60 120
17
10
D
(V)
230
230
(V)
57
40
10
9
(Hz)
0 1.5 30 60
7
6

Table of Contents