EasyManuals Logo

YASKAWA SGMSV User Manual

YASKAWA SGMSV
378 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #131 background imageLoading...
Page #131 background image
4.7 Absolute Encoders
4-45
4
Operation
Final absolute data P
M
is calculated by following formula.
P
E
=M× R+P
O
P
S
=M
S
× R+P
S
P
M
=P
E
-P
S
Note: The following formula applies in reverse mode. (Pn000.0 = 1)
P
E
= -M × R + P
O
P
S
= M
S
× R + P
S
'
P
M
= P
E
- P
S
Coordinate
value
Value of M
Reference position
(at setup)
Current position
-1 0 +1 +2 +3
+2+1-1 ±0
P
E
P
M
P
S
P
O
M × R
Signal Meaning
P
E
Current value read by encoder
M Rotational serial data
P
O
Number of initial incremental pulses
P
S
Absolute data read at setup (This is saved and controlled by the host controller.)
M
S
Rotational serial data read at setup
P
S
Number of initial incremental pulses read at setup
P
M
Current value required for the user’s system
R Number of pulses per encoder revolution (pulse count after dividing, value of Pn212)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA SGMSV and is the answer not in the manual?

YASKAWA SGMSV Specifications

General IconGeneral
BrandYASKAWA
ModelSGMSV
CategoryServo Drives
LanguageEnglish

Related product manuals