1.6 SERVOPACK Model Designation
1-21
1.6 SERVOPACK Model Designation
This section shows SERVOPACK model designation.
∗1. These amplifiers can be powered with single or three-phase.
∗2. SGDV-120A1A008000, a special version of the 1.5 kW amplifier can be used for single-phase operation.
∗3. SGDV-470A, -550A, -590A, -780A, -210D, -260D, -280D, and -370D are duct-ventilated types.
∗4. A resistor for the dynamic brake is not included. An external resistor for the dynamic brake can only be used with
400-V SERVOPACKs.
Note: If the option codes digits 8 to 13 are all zeros, they are omitted.
SGDV
Series
SGDV Σ-V Series
1st + 2nd + 3rd digits: Current
Voltage Code
Max. Allowable
Motor Capacity
(kW)
100 V
R70 0.05
R90 0.1
2R1 0.2
2R8 0.4
200 V
R70
*1
0.05
R90
*1
0.1
1R6
*1
0.2
2R8
*1
0.4
3R8 0.5
5R5
*1
0.75
7R6 1
120
*2
1.5
180 2
200 3
330 5
470
*3
6
550
*3
7.5
590
*3
11
780
*3
15
400 V
1R9 0.5
3R5 1
5R4 1.5
8R4 2
120 3
170 5
210
*3
6
260
*3
7.5
280
*3
11
370
*3
15
4th digit: Voltage
Code Voltage
F 100 V
A 200 V
D 400 V
5th + 6th digits: Interface Specifications
Code Interface
01
Analog voltage and pulse train reference,
rotational servomotor
05
Analog voltage and pulse train reference,
linear servomotor
11
MECHATROLINK-II communications ref-
erence, rotational servomotor
15
MECHATROLINK-II communications ref-
erence, linear servomotor
21
MECHATROLINK-III communications
reference, rotational servomotor
25
MECHATROLINK-III communications
reference, linear servomotor
11th + 12th digits: Software
Specification
Code Specification
00 Standard
–
7th digit: Design
Revision Order
1st + 2nd +
3rd digits
4th
digit
5th + 6th
digits
7th
digit
2R8 A
11
A
8th + 9th +
10th digits
000
8th + 9th + 10th digits: Hardware Specifications
Code Specifications
000 Base-mounted (standard)
001
Rack-mounted
*3
002 Va r ni sh ed
003
Rack-mounted
*3
and Varnished
008
Single-phase, 200-V Power Supply (SGDV-
120A1A008000)
020
Dynamic brake (DB)
*4
11th + 12th
digits
00
13th
digit
0
13th digit: Parameter
Specification
Code Specification
0 Standard