9 Troubleshooting
9.1.2 Troubleshooting of Alarms
9-22
FL-1
*3
:
System Alarm
SERVOPACK failure −
Turn the power supply to the SER-
VOPACK OFF and ON again. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
FL-2
*3
:
System Alarm
CPF00:
Digital Operator
Transmission Error 1
The contact between the digital
operator and the SERVOPACK is
faulty.
Check the connector contact.
Insert securely the connector or
replace the cable.
Malfunction caused by noise
interference.
−
Keep the digital operator or the
cable away from noise sources.
CPF01:
Digital Operator
Transmission Error 2
A digital operator fault occurred. −
Disconnect the digital operator and
then re-connect it. If the alarm still
occurs, the digital operator may be
faulty. Replace the digital operator.
A SERVOPACK fault occurred. −
Turn the power supply to the SER-
VOPACK OFF and ON again. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
∗3. These alarms are not stored in the alarm history and are displayed only in the panel display.
(cont’d)
Alarm Number:
Alarm Name
Cause Investigative Actions Corrective Actions