9 Troubleshooting
9.1.2 Troubleshooting of Alarms
9-22
FL-1
*3
:
System Alarm
SERVOPACK failure
Turn the power supply to the SER-
VOPACK OFF and ON again. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
FL-2
*3
:
System Alarm
CPF00:
Digital Operator
Transmission Error 1
The contact between the digital
operator and the SERVOPACK is
faulty.
Check the connector contact.
Insert securely the connector or
replace the cable.
Malfunction caused by noise
interference.
Keep the digital operator or the
cable away from noise sources.
CPF01:
Digital Operator
Transmission Error 2
A digital operator fault occurred.
Disconnect the digital operator and
then re-connect it. If the alarm still
occurs, the digital operator may be
faulty. Replace the digital operator.
A SERVOPACK fault occurred.
Turn the power supply to the SER-
VOPACK OFF and ON again. If the
alarm still occurs, the SERVO-
PACK may be faulty. Replace the
SERVOPACK.
∗3. These alarms are not stored in the alarm history and are displayed only in the panel display.
(cont’d)
Alarm Number:
Alarm Name
Cause Investigative Actions Corrective Actions

Table of Contents