EasyManuals Logo

YOKOGAWA DL850 ScopeCorder User Manual

YOKOGAWA DL850 ScopeCorder
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #182 background imageLoading...
Page #182 background image
App-21
IM DL850-03EN
Appendix
1
2
3
4
5
6
App
Index
Operation Key Soft Key Setting
FILE
Save_Waveform
Auto Naming Numbering
Data Type Binary
Range Main
Save_Setup
Auto Naming Numbering
Save_Others
Auto Naming Numbering
Data Type Screen Image
Format PNG
Color ON
MENU
Waveform Save ON
Waveform Save Setup
Auto Naming Numbering
Data Type Binary
Image Save OFF
Image Save Setup
Auto Naming Numbering
Image Format PNG
Color ON
Back Ground Normal
DISPLAY
Format Quad
Extra Window OFF
Graticule Grid
Scale Value ON
Setup
Allocation Mode Auto
Trace Label OFF
Dot Connect Line
Accumulate OFF
Manual Event OFF
Ch. Information Narrow
X-Y
Window1/2 OFF
Display OFF
Start Point –5 div
End Point 5 div
MODE
Auto
POSITION/DELAY
Position 50.0%
Delay 0.0 µs
SIMPLE/ENHANCED
Setting Simple
Source CH1
Slope Rising
Level 0 V
Hold Off 0.00 µs
Operation Key Soft Key Setting
CURSOR
Type OFF
Horizontal
Trace CH1
Cursor1 3.00 div
Cursor2 –3.00 div
Vertical
Trace CH1
Cursor1 –4.000 div
Cursor2 4.000 div
Marker
Marker # Marker1 X
Trace CH1
Position –3.000 div
Marker From Mark
Degree
Trace CH1
Cursor1 –4.000 div
Cursor2 4.000 div
RefValue 360
Ref1 –2.000 div
Ref2 2.000 div
H & V
Trace CH1
V-Cursor1 –4.000 div
V-Cursor2 4.000 div
H-Cursor1 3.00 div
H-Cursor2 –3.00 div
MEASURE
Mode OFF
Distal/Mesial/Proximal
Mode %
Distal 90.0%
Mesial 50.0%
Proximal 10.0%
High/Low Auto
Delay Setup
Mode OFF
Polarity Rising
Edge Count 1
Reference Trace
Range Main
Time Range1 –5.00 div
Time Range2 5.00 div
(When Mode is set to ON, Statistics)
1-Cycle Mode OFF
(When Mode is set to Cycle Statistics)
Cycle Trace CH1
Appendix 3 Default Values

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YOKOGAWA DL850 ScopeCorder and is the answer not in the manual?

YOKOGAWA DL850 ScopeCorder Specifications

General IconGeneral
Maximum Sampling Rate100 MS/s
Power Supply100 to 240 VAC, 50/60 Hz
Resolution16-bit
Operating Temperature5 to 40°C
Bandwidth20 MHz
Input TypesVoltage, Temperature, Strain, Acceleration, Frequency, Logic, Current
InterfacesEthernet, USB, GP-IB
Trigger ModesEdge, Window, Pattern
Number of ChannelsUp to 128 (with multiple input modules)
Memory CapacityUp to 2 G points (with /M4 option)

Related product manuals