2-32 IM 760301-01E
Bar Graph Display of Harmonic Data «See the
Expansion Function User’s Manual
IM760301-51E
On models with the advanced computation (/G6) or harmonic measurement (/G5) option,
the amplitude of each harmonic can be displayed on the bar graph. The horizontal axis
represents harmonic order, and the vertical axis represents the amplitude of each
harmonic.
Bar graph of voltage U1
Bar graph of current I1
Vector Display of Harmonics «See the
Expansion Function User’s Manual IM760301-
51E
During harmonic measurement on models with the advanced computation (/G6) or
harmonic measurement (/G5) option, vectors can be displayed to show the relationship
between the phase difference and amplitude (rms value) of the fundamental signals U(1)
and I(1) of each element that is assigned to the selected wiring unit.
Vector of wiring unit ΣA
2.8 Trend, Bar Graph, and Vector Displays