11 - 2 DS3608 Digital Scanner Product Reference Guide
Scanning Sequence Examples
In most cases, scanning one bar code sets the parameter value. For example, to transmit bar code data without the
UPC-A check digit, simply scan the Do Not Transmit UPC-A Check Digit bar code under Transmit UPC-A Check
Digit on page 11-17. The digital scanner issues a fast warble beep and the LED turns green, signifying a successful
parameter entry.
Other parameters, such as Set Length(s) for D 2 of 5 require scanning several bar codes. See the individual
parameter, such as Set Length(s) for D 2 of 5, for this procedure.
Errors While Scanning
Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Symbology Parameter Defaults
Table 11-1 lists the defaults for all symbology parameters. To change the default values, scan the appropriate bar
codes in this guide. These new values replace the standard default values in memory. To recall the default
parameter values, see Default Parameters on page 4-5.
NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, and miscellaneous default
parameters.
Table 11-1 Symbology Parameter Defaults
Parameter
Parameter
Number
SSI Number Default
Page
Number
Enable/Disable All Code Types
11-8
1D Symbologies
UPC/EAN
UPC-A 1 01h Enable
11-9
UPC-E 2 02h Enable
11-9
UPC-E1 12 0Ch Disable
11-10
EAN-8/JAN 8 4 04h Enable
11-10
EAN-13/JAN 13 3 03h Enable
11-11
Bookland EAN 83 53h Disable
11-11
Decode UPC/EAN/JAN Supplementals
(2 and 5 digits)
16 10h Ignore
11-12
User-Programmable Supplementals
Supplemental 1:
Supplemental 2:
579
580
F1h 43h
F1h 44h
000
11-15