4 - 30 DS3608 Digital Scanner Product Reference Guide
PDF Prioritization Timeout
Parameter # 720 (SSI # F1h D0h)
When PDF Prioritization is enabled, this timeout specifies how long the digital scanner attempts to decode a
PDF417 symbol before reporting the 1D bar code in the field of view.
Scan the following bar code, then scan four digits fromAppendix G, Numeric Bar Codes that specify the timeout in
milliseconds. For example, to enter 400 ms, scan the following bar code, then scan 0400. The range is 0 to 5000
ms, and the default is 200 ms.
NOTE The Hands-free Decode Session Timeout on page 4-24 should be set to a longer duration than PDF
Prioritization Timeout when configured.
PDF Prioritization Timeout

Table of Contents

Other manuals for Zebra DS3608

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS3608 and is the answer not in the manual?

Zebra DS3608 Specifications

General IconGeneral
TypeHandheld bar code reader
Wavelength655 nm
Sensor typeLaser
Scanner type1D/2D
Tilt reading angle0 - 360 °
Pitch reading angle0 - 65 °
Light levels (direct sunlight)0 - 108000 lx
Linear (1D) barcodes supportedCodabar, Code 11, Code 128, Code 39, Code 93, EAN 128, EAN 2, EAN 5, EAN-13, EAN-8, GS1 DataBar, Industrial 2 of 5, MSI, U.P.C., UPC-A, UPC-E
Optical sensor resolution (W x H)1280 x 960 pixels
2D (matrix & stacked) barcodes supportedAztec Code, Composite Codes, Data Matrix, Han Xin, MaxiCode, Micro QR Code, MicroPDF417, PDF417, QR Code, TLC-39
Input voltage4.5 - 5.5 V
Power source typeRS-232, USB
CertificationRoHS EN 50581: 2012
Product colorBlack, Grey
LED indicatorsYes
International Protection (IP) codeIP65
Standard interfacesKeyboard wedge, RS-232, USB
Connectivity technologyWired
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-30 - 50 °C
Operating relative humidity (H-H)5 - 95 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth132 mm
Width77 mm
Height185 mm
Weight304 g