11 - 12 DS3608 Digital Scanner Product Reference Guide
Decode UPC/EAN/JAN Supplementals
Parameter # 16 (SSI # 10h)
Supplementals are bar codes appended according to specific format conventions (e.g., UPC A+2, UPC E+2, EAN
13+2). The following options are available:
If you select Ignore UPC/EAN with Supplementals, and the digital scanner is presented with a
UPC/EAN plus supplemental symbol, the digital scanner decodes UPC/EAN and ignores the supplemental
characters.
If you select Decode UPC/EAN with Supplementals, the digital scanner only decodes UPC/EAN symbols
with supplemental characters, and ignores symbols without supplementals.
If you select Autodiscriminate UPC/EAN Supplementals, the digital scanner decodes UPC/EAN symbols
with supplemental characters immediately. If the symbol does not have a supplemental, the digital scanner
must decode the bar code the number of times set via UPC/EAN/JAN Supplemental Redundancy on page
11-15 before transmitting its data to confirm that there is no supplemental.
If you select one of the following Supplemental Mode options, the digital scanner immediately transmits
EAN-13 bar codes starting with that prefix that have supplemental characters. If the symbol does not have a
supplemental, the digital scanner must decode the bar code the number of times set via UPC/EAN/JAN
Supplemental Redundancy on page 11-15 before transmitting its data to confirm that there is no
supplemental. The digital scanner transmits UPC/EAN bar codes that do not have that prefix immediately.
Enable 378/379 Supplemental Mode
Enable 978/979 Supplemental Mode
Enable 977 Supplemental Mode
Enable 414/419/434/439 Supplemental Mode
Enable 491 Supplemental Mode
Enable Smart Supplemental Mode - applies to EAN-13 bar codes starting with any prefix listed
previously.
Supplemental User-Programmable Type 1 - applies to EAN-13 bar codes starting with a 3-digit
user-defined prefix. Set this 3-digit prefix using User-Programmable Supplementals on page 11-15.
Supplemental User-Programmable Type 1 and 2 - applies to EAN-13 bar codes starting with either of
two 3-digit user-defined prefixes. Set the 3-digit prefixes using User-Programmable Supplementals on
page 11-15.
Smart Supplemental Plus User-Programmable 1 - applies to EAN-13 bar codes starting with any prefix
listed previously or the user-defined prefix set using User-Programmable Supplementals on page 11-15.
Smart Supplemental Plus User-Programmable 1 and 2 - applies to EAN-13 bar codes starting with any
prefix listed previously or one of the two user-defined prefixes set using User-Programmable
Supplementals on page 11-15.
NOTE If you select 978/979 Supplemental Mode and are scanning Bookland EAN bar codes, see
Enable/Disable Bookland EAN on page 11-11 to enable Bookland EAN, and select a format using
Bookland ISBN Format on page 11-23.
NOTE To minimize the risk of invalid data transmission, select either to decode or ignore supplemental
characters.

Table of Contents

Other manuals for Zebra DS3608

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra DS3608 and is the answer not in the manual?

Zebra DS3608 Specifications

General IconGeneral
TypeHandheld bar code reader
Wavelength655 nm
Sensor typeLaser
Scanner type1D/2D
Tilt reading angle0 - 360 °
Pitch reading angle0 - 65 °
Light levels (direct sunlight)0 - 108000 lx
Linear (1D) barcodes supportedCodabar, Code 11, Code 128, Code 39, Code 93, EAN 128, EAN 2, EAN 5, EAN-13, EAN-8, GS1 DataBar, Industrial 2 of 5, MSI, U.P.C., UPC-A, UPC-E
Optical sensor resolution (W x H)1280 x 960 pixels
2D (matrix & stacked) barcodes supportedAztec Code, Composite Codes, Data Matrix, Han Xin, MaxiCode, Micro QR Code, MicroPDF417, PDF417, QR Code, TLC-39
Input voltage4.5 - 5.5 V
Power source typeRS-232, USB
CertificationRoHS EN 50581: 2012
Product colorBlack, Grey
LED indicatorsYes
International Protection (IP) codeIP65
Standard interfacesKeyboard wedge, RS-232, USB
Connectivity technologyWired
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)-30 - 50 °C
Operating relative humidity (H-H)5 - 95 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth132 mm
Width77 mm
Height185 mm
Weight304 g

Related product manuals