Page #127 background image
USER PREFERENCES & MISCELLANEOUS SCANNER OPTIONS 5 - 23
Unsolicited Heartbeat Interval
Parameter # 1118
The linear imager scanner supports sending Unsolicited Heartbeat Messages to assist in diagnostics. To
enable this feature and set the desired unsolicited heartbeat interval, scan one of the time interval bar codes
below, or scan Set Another Interval followed by four numeric bar codes from Appendix D, NUMERIC BAR
CODES (scan sequential numbers that correspond to the desired number of seconds).
Scan Disable Unsolicited Heartbeat Interval to turn off the feature.
The heartbeat event is sent as decode data (with no decode beep) in the form of:
MOTEVTHB:nnn
where nnn is a three digit sequence number starting at 001 and wrapping after 100.
NOTE For correct operation, you must disable Low Power Mode (see Low Power Mode on page 5-10).
10 seconds
(10)
1 minute
(60)
Set Another Interval
Disable Unsolicited Heartbeat Interval
(0)

Table of Contents

Other manuals for Zebra LI4278

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra LI4278 and is the answer not in the manual?

Zebra LI4278 Specifications

General IconGeneral
Wavelength617 nm
Read rate (max)547 reads/s
Decoding standardsUPC/EAN, UPC-A, UPC-E, UPC-E1, EAN-8/JAN 8, EAN-13/JAN 13, Bookland EAN, Bookland ISBN, UCC Coupon, ISBT 128, Code 39, Code 93, Matrix 2/5, Interleavd 2/5, Discrete 2/5, Codabar, MSI Chinese 2/5, GS1
Pitch reading angle-65 - 65 °
Light levels (direct sunlight)0 - 108000 lx
BluetoothYes
Bluetooth version2.1+EDR
Standard interfacesUSB, RS-232, RS-485
Operating time4320 min
Maximum operating distance100 m
CertificationFCC, ICES, IEC, RoHS, EN, UL
Product colorBlack
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)5 - 85 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth186 mm
Width70 mm
Height98 mm
Weight224 g