5 - 2 LI4278 Product Reference Guide
Scanning Sequence Examples
In most cases scanning one bar code sets the parameter value. For example, to set the beeper tone to high,
scan the High Frequency (beeper tone) bar code listed under Beeper Tone on page 5-7. The linear imager
scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry.
Other parameters require scanning several bar codes. See these parameter descriptions for this procedure.
Errors While Scanning
Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
User Preferences/Miscellaneous Option Parameter Defaults
Table 5-1 lists the defaults for preferences parameters. To change the default values:
Scan the appropriate bar codes in this guide. These new values replace the standard default values in
memory. To recall the default parameter values, scan the Default Parameters on page 5-4.
Configure the linear imager scanner using the 123Scan
2
configuration program (see 123SCAN2 on page
10-1).
Table 5-1
User Preferences Parameter Defaults
NOTE See Appendix A, STANDARD DEFAULT PARAMETERS for all user preferences, hosts, symbologies, and
miscellaneous default parameters.
In this guide, the parameter numbers listed are the same as the attribute numbers for these parameters.
Parameter
Parameter
Number
Default
Page
Number
User Preferences
Set Default Parameter Restore Defaults
5-4
Report Version N/A
5-5
Parameter Bar Code Scanning 236 Enable
5-5
Beep After Good Decode 56 Enable
5-6
Decode Illumination Indicator 859 Disable
5-6
Beeper Tone 145 Medium
5-7
Suppress Power Up Beeps 721 Do Not Suppress (Disable)
5-8
Beeper Volume 140 High
5-8
Beeper Duration 628 Medium
5-9
Hand-Held Trigger Mode 138 Level
5-9
Hands-Free Mode 630 Enable
5-10
Low Power Mode 128 Enable
5-10

Table of Contents

Other manuals for Zebra LI4278

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra LI4278 and is the answer not in the manual?

Zebra LI4278 Specifications

General IconGeneral
Wavelength617 nm
Read rate (max)547 reads/s
Decoding standardsUPC/EAN, UPC-A, UPC-E, UPC-E1, EAN-8/JAN 8, EAN-13/JAN 13, Bookland EAN, Bookland ISBN, UCC Coupon, ISBT 128, Code 39, Code 93, Matrix 2/5, Interleavd 2/5, Discrete 2/5, Codabar, MSI Chinese 2/5, GS1
Pitch reading angle-65 - 65 °
Light levels (direct sunlight)0 - 108000 lx
BluetoothYes
Bluetooth version2.1+EDR
Standard interfacesUSB, RS-232, RS-485
Operating time4320 min
Maximum operating distance100 m
CertificationFCC, ICES, IEC, RoHS, EN, UL
Product colorBlack
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)5 - 85 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth186 mm
Width70 mm
Height98 mm
Weight224 g

Related product manuals