RADIO COMMUNICATIONS 4 - 15
Auto-reconnect Feature
When in SPP Master or Cradle Host mode, the linear imager scanner automatically tries to reconnect to a
remote device when a disconnection occurs that is due to the radio losing communication. This can happen if
the linear imager scanner goes out of range with the remote device, or if the remote device powers down. The
linear imager scanner tries to reconnect for the period of time specified by the Reconnect Attempt Interval
setting. During that time the green LED continues to blink.
If the auto-reconnect process fails due to page time-outs, the linear imager scanner sounds a page timeout
beep (long low/long high) and enters low power mode. The auto-reconnect process can be re-started by pulling
the linear imager scanner trigger.
If the auto-reconnect process fails because the remote device rejects the connection attempt, the linear imager
scanner sounds a connection reject beep sequence (see Wireless Beeper Definitions on page 4-3) and deletes
the remote pairing address. If this happens, a pairing bar code must be scanned to attempt a new connection
to the remote device.
The linear imager scanner has memory available for storing a remote Bluetooth address for each Master mode
(SPP, Cradle). When switching between these modes, the linear imager scanner automatically tries to
reconnect to the last device it was connected to in that mode.
NOTE If a bar code is scanned while the auto-reconnect sequence is in process, a transmission error beep
sequence sounds and the data is not transmitted to the host. After a connection is reestablished, normal
scanning operation returns. For error beep sequence definitions, see Beeper and LED Definitions on page
2-1.
NOTE Switching between Bluetooth host types by scanning a host type bar code (page 4-3) causes the radio to
be reset. Scanning is disabled during this time. It takes several seconds for the linear imager scanner to
re-initialize the radio at which time scanning is enabled.

Table of Contents

Other manuals for Zebra LI4278

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zebra LI4278 and is the answer not in the manual?

Zebra LI4278 Specifications

General IconGeneral
Wavelength617 nm
Read rate (max)547 reads/s
Decoding standardsUPC/EAN, UPC-A, UPC-E, UPC-E1, EAN-8/JAN 8, EAN-13/JAN 13, Bookland EAN, Bookland ISBN, UCC Coupon, ISBT 128, Code 39, Code 93, Matrix 2/5, Interleavd 2/5, Discrete 2/5, Codabar, MSI Chinese 2/5, GS1
Pitch reading angle-65 - 65 °
Light levels (direct sunlight)0 - 108000 lx
BluetoothYes
Bluetooth version2.1+EDR
Standard interfacesUSB, RS-232, RS-485
Operating time4320 min
Maximum operating distance100 m
CertificationFCC, ICES, IEC, RoHS, EN, UL
Product colorBlack
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)5 - 85 %
Harmonized System (HS) code84716070
Weight and Dimensions IconWeight and Dimensions
Depth186 mm
Width70 mm
Height98 mm
Weight224 g

Related product manuals