1 - 10 MC67 Integrator Guide
•
On an PIM keypad, simultaneously press the red Power button and the and keys.
Performing a Clean Boot
A clean boot resets the MC67 to the factory default settings. All data in the Application folder is retained. You
must download the Clean Boot Package file from the Support Central web site, http://www.zebra.com/support
and install on the MC67.
To perform a clean boot:
1. Download the Clean Boot Package from the Support Central web site. Follow the instructions included in
the package for installing the package onto the MC67.
2. Perform a warm boot.
3. Immediately, as soon as the device starts to boot and before the splash screen is visible, press and hold
the left scan button.
4. Insert the MC67 into a powered cradle.
5. The MC67 updates and then resets.
6. Calibrate the screen.
Waking the MC67
The wake-up conditions define what actions wake up the MC67 after it has gone into suspend mode. The
MC67 can go into suspend mode by either pressing the Power button or automatically by Control Panel
time-out settings. To set the wake up conditions tap > Settings > System > Power > Wakeup.
CAUTION A clean boot should only be performed by an authorized system administrator. You must connect the
MC67 to AC power during a clean boot.
Removing AC power from the MC67 during a clean boot may render the MC67 inoperable.
Table 1-2
Wake-up Default Settings
Condition for Wake-up Power Button Automatic Time-out
MC67 is connected to a USB cable. Yes Yes
MC67 is connected toto a USB Host Device No No
A key is pressed. No Yes
The screen is touched. No No
Right Trigger is pressed. Yes Yes
Left Trigger is pressed. Yes Yes