Network Time Synchronization
The MC67 can be configured to synchronize the clock with the time from the carrier network. A registry key on
the MC67 has to be created to enable this feature.
Using a registry editor, navigate to the following:
[HKEY_LOCAL_MACHINE\SOFTWARE\Symbol\RIL\RHA\PH8]
Create the following key:
“SyncSystemTime”=dword:00000001
where:
dword:0 = disabled
dword:1 = enabled
After setting the registry key, warm boot the MC67.
Enhanced Operator Name String
The MC67 is enabled to download and display the name of the GSM network currently logged in to. Two
registry keys on the MC67 have to be edited to disable this feature.
Using a registry editor, navigate to each of the following:
[HKEY_LOCAL_MACHINE\Software\Microsoft\RIL]
Edit the following key:
“EonsEnable”=dword:1
[HKEY_LOCAL_MACHINE\Comm\Cellular\Ril]
Edit the following key:
“EONSEnable”=dword:1