Potential Duplicate Patients
Note: Patient records are evaluated using the following rules and actions to determine potential
duplicate patients after Data Synchronization, HF
A3 import, or import from an HFAII-i.
A flagged
patient record will show an exclamation point next to the patient record in the patient
selection list. When you select the patient record, you must choose whether to merge the patient
with the suspected duplicate or maintain the two patients as separate records before proceeding.
Separate Patients means that the patient records are not flagged and remain as independent
records
Potential duplicate patients are resolved as follows:
Patient ID Issuer of ID Name/Date of Birth Action
Match Match Match Merge
Match Match Different Flagged
Match Different Match Separate Patients
Match Different Different Separate Patients
Different Match Match Separate Patients
Different Match Different Separate Patients
Different Different Match Separate Patients
Different Different Different Separate Patients
See “Select Patient,” on page 4-1 and the Not
e at “Patient Search,” on page 4-1 for more
information about resolving potential duplicates.
To restore the database:
1. Select the backup from the list und
er Restoring data.
2. Select Replace.
3. Confirm your selection.
4. When the restore operation is complete, a confirmation displays. Select Restart
to restart the
instrument.
DICOM Configure additional DICOM communication options. See
“Networking,” on page 7-1 for further
details.
HFA II-i Configuration Configure an HFA II-i for data sharing. See “Data Synchronization,” on
page 10-1 for further details.
Duplicate Patients Check the database for potential duplicate patients. See Potential
Duplicate Patients for more information.
Back
Go back to the previous screen.
Button Function

Table of Contents

Other manuals for Zeiss Humphrey Field Analyzer 3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Zeiss Humphrey Field Analyzer 3 and is the answer not in the manual?

Zeiss Humphrey Field Analyzer 3 Specifications

General IconGeneral
BrandZeiss
ModelHumphrey Field Analyzer 3
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals