EasyManua.ls Logo

ZyXEL Communications IES-1248-51A - Page 312

ZyXEL Communications IES-1248-51A
654 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 44 Alarm
IES-1248-51V User’s Guide
312
eqpt (10006)warm_start info System warm-start.
eqpt (10007)alm_input critical There is an external alarm input.
eqpt (10008)voip_battery_fail critical There is a VoIP battery fault.
eqpt (10009)voip_clocl_fail critical There is a VoIP clock fault.
eqpt (10010)voip_ringer_fault critical The IES-1248-51V cannot ring due
to a hardware fault on the ringer
chip.??
sys (15000)reboot info The system restarted.
sys (15001)aco info An administrator cutoff (canceled)
an alarm.
sys (15002)alm_clear info An administrator cleared the
alarms.
sys (15003)login_fail minor V Someone used the wrong name or
password and failed to log in.
sys (15004)anti_spoofing minor The IES-1248-51V has detected the
same MAC address on more than
one subscriber port.
enet (20000)up info A Gigabit Ethernet interface is up.
enet (20001)down major V A Gigabit Ethernet interface is
down.
voip (25000)voip_temp_error critical The temperature of VoIP module
has reached 165 °C. The IES-1248-
51V releases this alarm when the
temperature goes down to 150 °C.
voip (25001)voip_dc_power_fail critical A DC power fault.
voip (25002)voip_ac_power_fail critical An AC power fault.
voip (25003)voip_ring_timer_fail info A firmware fault occurs when the
IES-1248-51V fails to start in SIP
mode.
voip (25004)voip_ring_rsrce_fail info The number of current incoming
VoIP calls has exceeded the total
RENs (ringer equivalency numbers)
the IES-1248-51V can support.
The IES-1248-51V only supports 1
REN for each subscriber port at the
time.
voip (25505)voip_ring_chd_fail info This alarm is no longer used.
Table 106 Alarm Descriptions (continued)
ALAR
M
CONDITION
SEVERIT
Y
CLEAR
ABLE
DESCRIPTION

Table of Contents