EasyManua.ls Logo

ZyXEL Communications IES-1248-51A - Voip Diagnostic Commands

ZyXEL Communications IES-1248-51A
654 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 68 VoIP Commands
IES-1248-51V User’s Guide
545
68.4 voip diagnostic Commands
Use these commands to perform a variety of standard Metallic Line Tests on the
subscriber ports.
Table 209 voip diagnostic Commands
COMMAND DESCRIPTION P
voip diagnostic mlt test
<port> <option> [force]
This command performs a variety of standard
Metallic Line Tests on the specified connection.
Perform specified MLT test item in specified
subscriber(s)
port: Port number, 1~48
option
: The type or types of test to be run.
Allowed values are:
all: Perform all tests on the line connected
to the specified port.
vac: Test the line’s AC voltage only.
vdc: Test the line’s DC voltage only.
rload: Test the line’s load resistance only.
riso: Test the line’s isolation resistance
only.
cap: Test the line’s capacitance only.
ren: Test the line’s ringer equivalent
number only.
ring: Test the line’s ring voltage only.
metering: Test the line’s metering voltage
only.
dialtone: Test dialtone
digit: Test digit
roh: Test ROH which is a tone sent at the
end of a call to indicate that the other party
has hung up.
user: User input DTMF tone
force:
Perform the test(s) immediately,
even if the specified port is in use.
M/
H
voip diagnostic mlt show
<port>
This command displays the results of the last
Metallic Line Test that was run on the specified
port.
L/L

Table of Contents