56.3.5 VLAN Frame Type Command Example
The following example sets the IES-1248-51V to accept only VLAN tagged
Ethernet frames on xDSL port 3.
56.3.6 VLAN CPU Show Command Example
The following example sets VLAN ID 2 to be the CPU (management) VLAN.
56.3.7 VLAN CPU Set Command Example
The following example sets VLAN ID 2 to be the CPU (management) VLAN.
56.3.8 Configuring Management VLAN Example
Note: After the following example configuration, you must connect to the first Ethernet
port through a VLAN aware device that is using the proper VLAN ID in order to
perform management.
By default, the IES-1248-51V’s xDSL ports are members of the management
VLAN (VID 1). The following procedure shows you how to configure a tagged VLAN
that limits management access to just one Ethernet port.
Note: Use the console port to configure the IES-1248-51V if you misconfigure the
management VLAN and lock yourself out.
1 Use the switch vlan set command to configure a VLAN ID (VID 3 in this
example) for managing the IES-1248-51V (the “management” or “CPU” VLAN).
ras> switch vlan frametype 3 tag
ras> switch vlan cpu set 2
ras> switch vlan cpu set 2
ras> switch vlan set 3 enet1:FT