Chapter 52 System Commands
IES-1248-51V User’s Guide
383
FAN RPM DOWN: dev:
<id> Limit:N value:N!
WARN A fan’s RPM went too low.
id - 1=Fan 1, 2=Fan 2, 3=Fan
Limit - minimum (low) fan (RPM)
value - the measured fan RPM
FAN RPM OK: dev: <id>
Limit:N value:N!
INFO A fan’s RPM returned to the normal range.
id - 1=Fan 1, 2=Fan 2, 3=Fan 3
Limit - maximum (high) or minimum fan (RPM) that had been
breached
value - the measured fan RPM
FAN RPM OVER: dev:
<id> Limit:N value:N!
WARN A fan’s RPM went too high.
id - 1=Fan 1, 2=Fan 2, 3=Fan 3
Limit - maximum (high) fan (RPM)
value - the measured fan RPM
Incorrect Password! WARN Someone attempted to use the wrong password to start a console,
telnet or FTP session (see the <process> field for the type of
session).
Session Begin! INFO A console, telnet or FTP session has begun (see the <process>
field for the type of session).
Session End! INFO A console telnet or FTP session has terminated (see the
<process> field for the type of session).
Sync with timeserver
<ip> failed!
WARN The device was not able to synchronize the time with the time
server at the listed IP address.
Sync with timeserver
<ip> successful!
INFO The device synchronized the time with the time server at the
listed IP address.
Received File <file>! INFO A file was uploaded to the IES-1248-51V by FTP.
file - received file’s name
Received Firmware
Checksum Error!
WARN A checksum error was detected during an attempted FTP firmware
upload.
Received Firmware
Invalid!
WARN Someone attempted to upload a firmware file with a wrong
identity via FTP.
Received Firmware Size
too large!
WARN The file size was too large with an attempted FTP firmware upload.
THERMO LOW VOLTAGE:
dev: <id> limit:
<threshold> value:
<voltage>!
WARN The device’s voltage went above the accepted operating range.
id - 1=1.2v, 2=1.8v, 3=3.3v, 4=24v
threshold - voltage limit
voltage - voltage of the DC power when logged
Table 136 Log Messages (continued)
LOG MESSAGE TYPE DESCRIPTION