EasyManua.ls Logo

ZyXEL Communications IES-1248-51A - Page 383

ZyXEL Communications IES-1248-51A
654 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 52 System Commands
IES-1248-51V User’s Guide
383
FAN RPM DOWN: dev:
<id> Limit:N value:N!
WARN A fan’s RPM went too low.
id - 1=Fan 1, 2=Fan 2, 3=Fan
Limit - minimum (low) fan (RPM)
value - the measured fan RPM
FAN RPM OK: dev: <id>
Limit:N value:N!
INFO A fan’s RPM returned to the normal range.
id - 1=Fan 1, 2=Fan 2, 3=Fan 3
Limit - maximum (high) or minimum fan (RPM) that had been
breached
value - the measured fan RPM
FAN RPM OVER: dev:
<id> Limit:N value:N!
WARN A fan’s RPM went too high.
id - 1=Fan 1, 2=Fan 2, 3=Fan 3
Limit - maximum (high) fan (RPM)
value - the measured fan RPM
Incorrect Password! WARN Someone attempted to use the wrong password to start a console,
telnet or FTP session (see the <process> field for the type of
session).
Session Begin! INFO A console, telnet or FTP session has begun (see the <process>
field for the type of session).
Session End! INFO A console telnet or FTP session has terminated (see the
<process> field for the type of session).
Sync with timeserver
<ip> failed!
WARN The device was not able to synchronize the time with the time
server at the listed IP address.
Sync with timeserver
<ip> successful!
INFO The device synchronized the time with the time server at the
listed IP address.
Received File <file>! INFO A file was uploaded to the IES-1248-51V by FTP.
file - received file’s name
Received Firmware
Checksum Error!
WARN A checksum error was detected during an attempted FTP firmware
upload.
Received Firmware
Invalid!
WARN Someone attempted to upload a firmware file with a wrong
identity via FTP.
Received Firmware Size
too large!
WARN The file size was too large with an attempted FTP firmware upload.
THERMO LOW VOLTAGE:
dev: <id> limit:
<threshold> value:
<voltage>!
WARN The device’s voltage went above the accepted operating range.
id - 1=1.2v, 2=1.8v, 3=3.3v, 4=24v
threshold - voltage limit
voltage - voltage of the DC power when logged
Table 136 Log Messages (continued)
LOG MESSAGE TYPE DESCRIPTION