EasyManua.ls Logo

ABB ACS850 - Resolver Conf; Pulse Enc Conf

ABB ACS850
370 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
252 Parameters
92
92 Resolver conf
Resolver configuration. See also section Encoder support on
page 63.
92.01 Resolv polepairs Selects the number of pole pairs.
1 … 32 Number of pole pairs. 1 = 1
92.02 Exc signal ampl Defines the amplitude of the excitation signal.
4.0 … 12.0 Vrms Amplitude of excitation signal. 10 = 1 Vrms
92.03 Exc signal freq Defines the frequency of the excitation signal.
1 … 20 kHz Frequency of excitation signal. 1 = 1 kHz
93
93 Pulse enc conf
Pulse encoder configuration. See also section Encoder
support on page 63.
93.01 Enc1 pulse nr Defines the pulse number per revolution for encoder 1.
0 … 65535 Number of pulses for encoder 1. 1 = 1
93.02 Enc1 type Selects the type of the encoder 1.
Quadrature Quadrature encoder (has two channels, A and B) 0
Single track Single track encoder (has one channel, A) 1
93.03 Enc1 sp CalcMode Selects the speed calculation mode for encoder 1.
A&B all Channels A and B: Rising and falling edges are used for
speed calculation. Channel B: Defines the direction of
rotation.
Notes:
When single track mode has been selected by parameter
93.02 Enc1 type, this setting acts like the setting A all.
When single track mode has been selected by parameter
93.02 Enc1 type, the speed is always positive.
0
A all Channel A: Rising and falling edges are used for speed
calculation. Channel B: Defines the direction of rotation.
Note: When single track mode has been selected by
parameter 93.02 Enc1 type, the speed is always positive.
1
A rising Channel A: Rising edges are used for speed calculation.
Channel B: Defines the direction of rotation.
Note: When single track mode has been selected by
parameter 93.02 Enc1 type, the speed is always positive.
2
A falling Channel A: Falling edges are used for speed calculation.
Channel B: Defines the direction of rotation.
Note: When single track mode has been selected by
parameter 93.02 Enc1 type, the speed is always positive.
3
Auto rising One of the above modes is selected automatically depending
on the pulse frequency as follows:
4
No. Name/Value Description FbEq
Pulse frequency of the channel(s) Mode used
< 2442 Hz A&B all
2442…4884 Hz A all
> 4884 Hz A rising