258 Parameters
99.08 Mot nom freq Defines the nominal motor frequency.
Note: This parameter cannot be changed while the drive is
running.
5.0 … 500.0 Hz Nominal frequency of the motor. 10 = 1 Hz
99.09 Mot nom speed Defines the nominal motor speed. The setting must match the
value on the rating plate of the motor.
Note: This parameter cannot be changed while the drive is
running.
Note: For safety reasons, after ID run, the maximum and
minimum speed limits (parameters 20.01 and 20.02) are
automatically set to a 1.2 times bigger value than the nominal
motor speed.
0 … 10000 rpm Nominal speed of the motor. 1 = 1 rpm
99.10 Mot nom power Defines the nominal motor power. The setting must match the
value on the rating plate of the motor. If multiple motors are
connected to the drive, enter the total power of the motors.
The unit is selected by parameter 16.17 Power unit.
Note: This parameter cannot be changed while the drive is
running.
0.00 … 10000.00
kW
Nominal power of the motor. 100 = 1 kW
99.11 Mot nom cosfii Defines the cosphi of the motor for a more accurate motor
model. (Not applicable to permanent magnet motors and
synchronous reluctance motors.) Not obligatory; if set, should
match the value on the rating plate of the motor.
Note: This parameter cannot be changed while the drive is
running.
0.00 … 1.00 Cosphi of the motor. 100 = 1
99.12 Mot nom torque Defines the nominal motor shaft torque for a more accurate
motor model. Not obligatory.
Note: This parameter cannot be changed while the drive is
running.
0 … 2147483.647
Nm
Nominal motor torque. 1000 = 1 N•m
No. Name/Value Description FbEq

Table of Contents

Other manuals for ABB ACS850

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS850 and is the answer not in the manual?

ABB ACS850 Specifications

General IconGeneral
SafetySTO (Safe Torque Off)
CommunicationCANopen
EnclosureIP21
Output VoltageUp to 1000 V DC
Protection FeaturesOvercurrent, Overvoltage, Undervoltage
Cooling MethodAir or liquid cooling
Input Voltage380 to 690 V AC

Related product manuals