A.5 Communication Area Mapping Appendix A: Communication
290 493-0736-11 (6-2)
Table 1 I/O RAM Map.
Note 1. For ‘GS Mode’, the value 0 (zero) denotes Off, and the value 1 (one)
denotes On.
Errors Read 0058
16
0130
8
0088
10
AI5 Int
Err
AI4 Int
Err
AI3 Int
Err
AI2 Int
Err
AI1 Int
Err
AO3 Int
Err
AO2 Int
Err
AO1 Int
Err
Warnings Read 0060
16
0140
8
0096
10
AI5 Int
Warn
AI4 Int
Warn
AI3 Int
Warn
AI2 Int
Warn
AI1 Int
Warn
AO3 Int
Warn
AO2 Int
Warn
AO1 Int
Warn
Warnings Read 0068
16
0150
8
0104
10
AA Src
Off
DA Src
Off
OC Src
Off
OF Src
Off
CLPM L2 CLPM L1 Arith
Err
Calibr Err
Warnings Read 0070
16
0160
8
0112
10
AU Src
Off
DI Src
Off
DIC Src
Off
DU Src
Off
FA Src
Off
FL Src
Off
FO Src
Off
SP Src
Off
Warnings Read 0078
16
0170
8
0120
10
Adapt
Warn L2
Adapt
Warn L1
Tun Warn
L2
Tun
Warn L1
Tun Abort
L2
Tun Abort
L1
AI Src
Off
A IC Src
Off
Information Read 0080
16
0200
8
0128
10
Hi 2 Hi 1 LoLo 3 LoLo 2 LoLo 1 HiHi 3 HiHi 2 HiHi 1
Information Read 0088
16
0210
8
0136
10
Pos Dev
1
Neg Dev
3
Neg Dev
2
Neg Dev
1
Lo 3 Lo 2 Lo 1 Hi 3
Information Read 0090
16
0220
8
0144
10
Tun Init
L2
Tun Init
L1
Pos Dev
3
Pos Dev 2
Information Read 0098
16
0230
8
0152
10
Tun
Phase 8
L1
Tun
Phase 7
L1
Tun
Phase 6
L1
Tun
Phase 5
L1
Tun
Phase 4
L1
Tun Phase
3 L1
Tun
Phase 2
L1
Tun Phase
1 L1
Information Read 00A0
16
0240
8
0160
10
Tun
Phase 8
L2
Tun
Phase 7
L2
Tun
Phase 6
L2
Tun
Phase 5
L2
Tun
Phase 4
L2
Tun Phase
3 L2
Tun
Phase 2
L2
Tun Phase
1 L2
Control Read/Write 00B0
16
260
8
176
10
Controller
Action,
Loop 1
GS
Mode,
Loop 1
Control Read/Write 00B8
16
270
8
186
10
Controller
Action,
Loop 2
GS
Mode,
Loop 2
Control Read/Write 00C0
16
300
8
192
10
Tuner
Strt/Abort
Loop 1
a
Control Read/Write 00C8
16
310
8
200
10
Tuner
Strt/Abort
Loop 2
a
Control Read/Write 00D0
16
320
8
208
10
Decrease
Loop 2
(see note
3)
Decrease
Loop 1
(see note
3)
Increase
Loop 2
(see note
3)
Increase
Loop 1
(see note
3)
Alarm
acknowl.
a. The value 1 (one) denotes start and the value 0 (zero) denotes abort
Variable Access Address Bit Position
Hex Oct Dec 7 6 5 4 3 2 1 0

Table of Contents