5 Calibration information
5.10. Checking the calibration position
3HAC030005-001 Revision: -188
© Copyright 2006 ABB. All rights reserved.
4. Release the brakes, using
the break release button
(A).
xx070000043
5. Push the upper arm axis
1-3 very gently against the
calibration device (A).
NOTE!
Always check one axis a
time, starting with axis 1.
xx0700000626
6. Check that the position of
axes 1 is -47.00° for std.
and -44.80° for 800.
xx0700000628
7. If the axis position is not
ok.
Calibrate the axis, shown in section Calibration IRB 360
axis 1-3 on page 175.
8. If the axis position is ok
return to step 4 and check
axis 2 and 3.
Action Note
Continued