EasyManua.ls Logo

ABB IRB 6640 - Page 338

ABB IRB 6640
440 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 Repair
4.6.2. Replacement of motor axis 2
3HAC026876-001 Revision: F336
© Copyright 2007-2010 ABB. All rights reserved.
10. Secure the motor with four attachment screws
and plain washers.
M10 x 40, tightening torque: 50 Nm.
Reused screws may be used, providing
they are lubricated as detailed in the
section Screw joints on page 405 before
fitting.
11. Disconnect the brake release voltage.
12. Reconnect all connectors beneath the motor
cover.
Connect in accordance with markings
on connectors.
13. Refit the cable gland cover at the cable exit
with its two attachment screws.
Shown in the figure Location of motor on
page 332.
14. Refit the cover on top of the motor with its four
attachment screws.
Make sure the cover is tightly sealed!
15. Remove the lock screw from the hole for lock
screw.
Shown in the figure Location of motor on
page 332.
16. Perform a leak down test. Detailed in Performing a leak-down test
on page 196.
17. Refill the gearbox with oil. Detailed in the section Oil change,
gearbox axis 2 on page 168.
18. Recalibrate the robot. Calibration is detailed in a separate
calibration manual enclosed with the
calibration tools.
General calibration information is
included in the section Calibration infor-
mation.
19.
DANGER!
Make sure all safety requirements are met
when performing the first test run. These are
further detailed in the section DANGER - First
test run may cause injury or damage! on page
41.
Action Note
Continued

Table of Contents