NoteAction
Disconnect the air hoses from the L-shaped con-
nectors.
2
xx2300000542
For robots with C1 cabling
Disconnect the connector.
• R2.C1
3
For robots with C2 cabling
Disconnect the connector.
• R1.C2
Tip
Cut the cable straps for the R1.C2 at the same
time.
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
4
Tip
The connector clip has to be pressed (1) and
pushed forward (2) to separate the R1.C2 (for C2
cabling).
xx1800002943
xx2300000544
Snap loose and remove the female head of the
connectors from the bracket.
Note
The harness are not visible due to the cleanness
requirements of the illustration. They are still ex-
isting inside the cable ferrule in the actual situ-
ation.
5
Continues on next page
Product manual - IRB 930 123
3HAC086009-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the process hub
Continued