Refitting the outer arm to the inner arm
NoteAction
CAUTION
Whenever parting/mating motor and gearbox, the
gears may be damaged if excessive force is used.
1
xx2300000603
Refit the gear gasket to the axis-2 gear unit.2
Screws: Hex socket head cap
screw M10x25 12.9 Gleitmo
603+Geomet 500 (6 pcs)
Refit the outer arm to the inner arm.
Tip
When the gear unit is in the right position, you
can hear a clear "Click".
3
Tightening torque:55 Nm
Screws: Hex socket head cap
screw M6x20 12.9 Gleitmo
603+Geomet 500 (3 pcs)
Tightening torque:10 Nm
Refit the screws.
Note
The two screw holes under the axis-2 belt location
are left empty.
4
xx2300000517
Refitting the cable arm
NoteAction
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
Refit the cable arm to the inner arm and outer arm.2