Note/IllustrationAction
xx1900002447
Push the digital base into the bracket
until you hear a clear clicking sound.
3
Connect the adapter cable to the digital
base.
• K5.1.X5/K3.1.X5 - A2.X4/K4.X7
Note
If the Ethernet extension switch is
installed, connect and disconnect
the connector K5.1.X5/K3.1.X5
to/from K4.X7.
If the Ethernet extension switch is
not installed, connect and discon-
nect the connector
K5.1.X5/K3.1.X5 to/from A2.X4.
• K5.1.X4 - K2.X3
• The harness connected to I/O unit
by customer
4
Concluding procedure
Note/IllustrationAction
Closing the door on page 176.Close the door.1
Perform the function tests to verify that
the safety features work properly, see
Function tests on page 166.
2
Product manual - OmniCore V250XT 225
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.2.7 Replacing the safety digital base device
Continued