EasyManua.ls Logo

ABB OmniCore V250XT - Page 225

ABB OmniCore V250XT
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Note/IllustrationAction
xx1900002447
Push the digital base into the bracket
until you hear a clear clicking sound.
3
Connect the adapter cable to the digital
base.
K5.1.X5/K3.1.X5 - A2.X4/K4.X7
Note
If the Ethernet extension switch is
installed, connect and disconnect
the connector K5.1.X5/K3.1.X5
to/from K4.X7.
If the Ethernet extension switch is
not installed, connect and discon-
nect the connector
K5.1.X5/K3.1.X5 to/from A2.X4.
K5.1.X4 - K2.X3
The harness connected to I/O unit
by customer
4
Concluding procedure
Note/IllustrationAction
Closing the door on page 176.Close the door.1
Perform the function tests to verify that
the safety features work properly, see
Function tests on page 166.
2
Product manual - OmniCore V250XT 225
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.2.7 Replacing the safety digital base device
Continued

Table of Contents

Related product manuals