EasyManua.ls Logo

ABB OmniCore V250XT - Page 280

ABB OmniCore V250XT
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Required documents
NoteArticle numberDocument
3HAC074000-008Circuit diagram - OmniCore
V250XT
Removing the safety module
Note
The safety module is part of an assembly group, secured on a process plate. To
remove the safety module, either lift out the assembly group and then remove
the safety module, or take out the parts on top of the main computer and then
remove the safety module.
Preparations
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 28.
1
Opening the door on page 176.Open the door.2
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 43.
3
xx2100000318
Continues on next page
280 Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.2.13 Replacing the safety module
Continued

Table of Contents

Related product manuals