EasyManua.ls Logo

ABB OmniCore V250XT - Page 304

ABB OmniCore V250XT
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Note/IllustrationAction
xx2100002198
Remove the screw holding the break
resistor bleeder bracket.
2
Remove the break resistor bleeder and
its bracket.
3
Refitting the break resistor bleeder
Refitting the break resistor bleeder
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 28.
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 43.
2
xx2100000318
Refit the break resistor bleeder and its
bracket.
3
xx2100002198
Secure the screw holding the break res-
istor bleeder bracket.
4
Remove any remaining old shrink tubes
from the cables.
5
Continues on next page
304 Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.2.17 Replacing the break resistor bleeder
Continued

Table of Contents