Note/IllustrationAction
xx2100002198
Remove the screw holding the break
resistor bleeder bracket.
2
Remove the break resistor bleeder and
its bracket.
3
Refitting the break resistor bleeder
Refitting the break resistor bleeder
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 28.
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 43.
2
xx2100000318
Refit the break resistor bleeder and its
bracket.
3
xx2100002198
Secure the screw holding the break res-
istor bleeder bracket.
4
Remove any remaining old shrink tubes
from the cables.
5
Continues on next page
304 Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.2.17 Replacing the break resistor bleeder
Continued