Note/IllustrationAction
Apply shrink tubes on the cables. The
shrink tubes should overlap by 5-7 mm.
6
Reconnect the three cables.7
Concluding procedure
Note/IllustrationAction
Refitting the rear cover on page 178.Refit the rear cover of the controller.1
Make sure that the filter cover plate is
correctly positioned.
2
Perform the function tests to verify that
the safety features work properly, see
Function tests on page 166.
3
Product manual - OmniCore V250XT 305
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.2.17 Replacing the break resistor bleeder
Continued