OmniCore V250XTReference to circuit diagram
BaselineX2Manipulator signal connector
(SMB)
BaselineX4FlexPendant connector (HMI)
BaselineX1Motor connector
BaselineA2.K3Motion Safety
Baseline
i
K7Connected Services Gateway
(with antenna for 3G and WiFi)
BaselineG1-G4Standard fan
BaselineG5Internal fan
BaselineA2Main computer
BaselineQ0Incoming mains switch
BaselineK2Robot signal exchange proxy
BaselineX0Incoming mains connector
i
Baseline is 3G. Wired or WiFi available as option.
OmniCore V250XT, Options
OmniCore V250XTReference to circuit diagram
OptionK5.1Scalable I/O
OptionK5.2Additional I/O
K5.3
K5.4
OptionK3.1Safety digital base I/O
OptionB1Conveyor tracking module
OptionK4Ethernet switch
OptionT5, T8Process power supply
OptionT6, T9ODVA power supply
OptionAir filter
OptionX0Incoming mains cable gland
Dimensions
ValueParameter
650 mmWidth
480 mmDepth
960 mmHeight
Weight
The table shows the weight of the controller.
WeightController
83 kgOmniCore V250XT
Continues on next page
Product manual - OmniCore V250XT 37
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
2 Controller description
2.2 Technical data for OmniCore V250XT controller
Continued