EasyManua.ls Logo

ABB OmniCore V250XT - Page 388

ABB OmniCore V250XT
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NoteAction
Verify that DC_OUT (X4) is 650 +/- 3% VDC.
If the measured voltage is normal, the
unit might be faulty. See Replacing the
power unit on page 250.
If the measured voltage is normal and
MODULE STATUS LED is steady red,
read error messages on FlexPendant
and take action. Proceed with step 13.
If the measured voltage is abnormal and
MODULE STATUS LED is steady green,
proceed with step 15.
Activate safe CTRL signals and
verify DC_OUT.
12
If the error message is insufficient, pro-
ceed with step 14.
If an error was resolved, restart from step
1.
Check error message on FlexPend-
ant and take appropriate action.
13
1 Turn off power for 10 seconds.
2 Disconnect DC_OUT (X4 and X8).
3 Turn on power again.
4 Activate CTRL signals.
5 The DC-BUS High Voltage LED should
turn yellow/orange and DC_OUT should
be charged to nominal voltage.
6 Verify that the disconnected load is
within specification and is not broken.
If DC_OUT is OK and DC-BUS High
Voltage is on with the loads disconnec-
ted, proceed with step 17.
If DC_OUT is not OK, the unit may be
faulty, see Replacing the power unit on
page 250.
Test starting with DC_OUT loads
disconnected.
14
If the connection and cables seem OK, proceed
with step 11.
Make sure that the cables are con-
nected properly at both ends:
CTRL/FB (A1.X2)
15
If there is a problem with the connection, pro-
ceed with step 16.
If the connection and cables seem OK, restart
from step 1.
Replace cables:
CTRL/FB (A1.X2)
16
If there is a problem with the connection, see
Troubleshooting the drive unit on page 376.
If the connection and cables seem OK, proceed
with step 18.
Make sure that the cables are con-
nected properly at both ends:
DC_OUT (X4 and X8)
17
If DC_OUT is not OK, the unit may be faulty,
see Replacing the power unit on page 250.
If DC_OUT is not OK, the unit may be faulty,
see Replacing the power unit on page 250.
Replace cables:
DC_OUT (X4 and X8)
18
388 Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
7 Troubleshooting
7.3.4 Troubleshooting the power unit
Continued

Table of Contents

Related product manuals