2 Select Public Network and configure the network interface. Tap Apply.
xx2100002086
I/O Network
The I/O Network is needed when an Industrial Ethernet network must be isolated
from the Public Network. It can be configured either in RobotStudio or from the
FlexPendant:
Defining network settings in RobotStudio:
1 In the Configuration browser, right-click the controller and select
Properties\Network Settings and then I/O Network.
2 In the I/O Network window, configure the network interface and click
OK.
xx2200000389
Continues on next page
90 Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
3 Installation and commissioning
3.5.7 Ethernet networks on OmniCore