Defining network settings on the FlexPendant:
1 On the start screen, tap Settings, and then select Network from the
menu.
2 Select I/O Network and configure the network interface. Tap Apply.
xx2100002097
Firewall settings
The Firewall Management function is used to configure the network firewall on the
controller. Configuration is done in RobotStudio under
Configuration\Communication\Firewall Manager where pre-configured Network
Services can be enabled or disabled:
xx1900000352
Note
Only pre-registered Network Services can be configured in the Firewall Manager
settings. The user cannot add new Network Services in the Firewall Manager
and can only change the parameters Enable on Public Network, Enable on
Private Network and Enable on I/O Network for pre-registered Network Services.
Note
Only users with UAS grant Modify network security properties can modify the
firewall settings.
For more information, see Technical reference manual - System parameters.
Product manual - OmniCore V250XT 91
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
3 Installation and commissioning
3.5.7 Ethernet networks on OmniCore
Continued