-EN Rev. E Operating instruction SCK Gas Sampling System 121
After switching on: working on the cooling module
Risk of injury in the area of the gas sampling system due to moving or fall-
ing parts, hot surfaces, hot cooling water, anti-freeze, compressed air,
lubricating oil
Wear general personal protective equipment:
Closed overalls with long trousers and long sleeves
Safety shoes
Safety gloves suitable for mechanical work
Safety glasses
Protective helmet
If necessary, additional protective equipment if prescribed by the operator.
Danger of electric shock when control cabinet is open, open connection or
terminal boxes
Only specialized electrical personnel may work on the electrical system.
Observe national regulations pertaining to electrical equipment.
The main terminals -X30, -X40 and the input terminals of the main
switches -Q30, -Q40 are live even when the main switches are off.
All metallic parts in the environment that can be touched at the same
time as the machine must also be grounded together.
Check pre-protection according to the documentation.
Danger of injury to skin and eyes in the event of contact with cooling water
or anti-freeze.
Avoid contact with the cooling water and the anti-freeze.
Wash any cooling water and anti-freeze off the skin immediately with
water and soap.
If cooling water or anti-freeze gets in the eyes despite protective glass-
es, rinse them thoroughly under running water, holding the eyelids open.
Observe instructions in the anti-freeze manufacturer's safety data sheet.
Risk of falling on slippery floor due to escaped or spilled cooling water and
lubricating oil or dirt
Always keep the floor around the gas sampling system clean and dry.
Control cabinet key to open the control cabinet
The service switch is in the
ON
position, the gas sampling probe is retracted
from the kiln (see
Operating the service switch
on page 161).
Mechanical, thermal
and material dangers
Current-carrying
components
Harmful
anti-freeze
Slippery floor
Tools required
Requirements